{"id":975,"date":"2025-01-08T13:37:09","date_gmt":"2025-01-08T12:37:09","guid":{"rendered":"http:\/\/localhost\/gassample\/?page_id=975"},"modified":"2025-09-17T11:38:53","modified_gmt":"2025-09-17T09:38:53","slug":"tgtu","status":"publish","type":"page","link":"https:\/\/gassample.com\/en\/tgtu\/","title":{"rendered":"TGTU"},"content":{"rendered":"<p><section class=\"kc-elm kc-css-901144 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-11352 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-60953 kc-title-wrap\">\n\n\t<h2 class=\"kc_title\">TGTU III Plant Modernization - Achieving Higher Measurement Accuracy.<\/h2>\n<\/div>\n<div class=\"kc-elm kc-css-288209 kc_text_block\"><\/p>\n<p><span class=\"fontstyle0\">MARCIN MASEK- GAS SAMPLE SP. Z O.O.<\/span><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-95453 kc-raw-code\"><a name=\"\u201dtop\u201d\"> <\/a><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-340168 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-40741 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-292377 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">INTRODUCTION<\/h3>\n<\/div>\n<div class=\"kc-elm kc-css-345747 kc_text_block\"><\/p>\n<p class=\"MsoNormal\">In the framework of the TGTU III (Tail Gas Treatment Unit) industrial plant modernization project, three advanced analytical systems were implemented: high-pressure superheated steam conductivity measurement, acidic water pH measurement, and two boiler blowdown conductivity systems.<\/p>\n<p class=\"MsoNormal\">A unique aspect of this project was the development of a dedicated diagnostic solution for sample flow signaling. This solution was created at the client's special request, enabling more precise and secure monitoring and control of the sample flow.<\/p>\n<p class=\"MsoNormal\">\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-532185 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-319108 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-604401 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">SUPERHEATED STEAM CONDUCTIVITY SYSTEM<\/h3>\n<\/div>\n<\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-845290 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-906044 kc_col-sm-8 kc_column kc_col-sm-8\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-803544 kc_text_block\"><\/p>\n<p class=\"MsoNormal\">The system monitors steam at temperatures up to 300\u00b0C and a pressure of 32 bar. The sample is cooled and condensed, then measured with a conductivity probe. A key element of the system is the HACH Polymetron 9500 transmitter, which compensates for measurements based on sample temperature, ensuring accuracy in dynamic process conditions. The system was designed to fit into a thermally insulated and purged cabinet, which protects the measuring components from harmful environmental conditions, such as an H2S atmosphere.<\/p>\n<p class=\"MsoNormal\">\n<\/div><\/div><\/div><div class=\"kc-elm kc-css-847241 kc_col-sm-4 kc_column kc_col-sm-4\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-304948 kc_shortcode kc_single_image\">\n\n        <a rel=\"prettyPhoto\" class=\"kc-pretty-photo\" href=\"https:\/\/gassample.com\/wp-content\/uploads\/2025\/01\/asset-get.class.image_.png\" title=\"Hach Polymetron 9500\" target=\"\">\n        <img decoding=\"async\" src=\"https:\/\/gassample.com\/wp-content\/uploads\/2025\/01\/asset-get.class.image_-250x250xc.png\" class=\"\" alt=\"Hach Polymetron 9500\" \/>    <\/a>\n    \t    <p class=\"scapt\">Hach Polymetron 9500<\/p>\n\t    <\/div>\n<\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-870414 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-782343 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-268578 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">ACIDIC WATER PH MEASUREMENT SYSTEM<\/h3>\n<\/div>\n<\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-434306 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-634824 kc_col-sm-3 kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-747237 kc_shortcode kc_single_image\">\n\n        <a rel=\"prettyPhoto\" class=\"kc-pretty-photo\" href=\"https:\/\/gassample.com\/wp-content\/uploads\/2025\/01\/tgtu3.jpg\" title=\"Rys tech uk\u0142adu TGTU\" target=\"\">\n        <img decoding=\"async\" src=\"https:\/\/gassample.com\/wp-content\/uploads\/2025\/01\/tgtu3-269x300.jpg\" class=\"\" alt=\"Rys tech uk\u0142adu TGTU\" \/>    <\/a>\n    \t    <p class=\"scapt\">Cabinet with conditioning system.<\/p>\n\t    <\/div>\n<\/div><\/div><div class=\"kc-elm kc-css-79135 kc_col-sm-9 kc_column kc_col-sm-9\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-161544 kc_text_block\"><\/p>\n<p class=\"MsoNormal\">Designed to operate with water at 92\u00b0C and a pressure of 5.8 bar, the system allows for continuous pH monitoring. Thanks to integrated cooling and filtration, the sample reaches the Hach 5336T probe under ideal measurement conditions. A key feature of this system is the ability to compensate for measurements based on temperature and to continuously monitor the sample's temperature and flow, which enables remote control of the system parameters.<\/p>\n<p class=\"MsoNormal\">\n<\/div>\n<div class=\"kc-elm kc-css-700972 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">TWO BOILER BLOWDOWN CONDUCTIVITY SYSTEMS<\/h3>\n<\/div>\n<div class=\"kc-elm kc-css-688405 kc_text_block\"><\/p>\n<p class=\"MsoNormal\">Two conductivity systems for boiler blowdown were designed analogously to the above systems. Each system uses HACH technology for liquid conductivity measurements, as well as remote monitoring of sample temperature and flow. Each system also allows for a laboratory sample to be taken for diagnostic and service purposes.<\/p>\n<p class=\"MsoNormal\">\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-358340 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-588358 kc_col-sm-9 kc_column kc_col-sm-9\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-225708 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">INNOVATIVE DIAGNOSTIC SOLUTION FOR ROTAMETERS<\/h3>\n<\/div>\n<div class=\"kc-elm kc-css-466821 kc_text_block\"><\/p>\n<p class=\"MsoNormal\"><span style=\"mso-bidi-font-weight: bold;\">One of the most interesting elements of the project was the creation of a proprietary flow diagnostic system for rotameters, which were not equipped with factory signaling.<\/span><\/p>\n<p class=\"MsoNormal\">At the client's request, a solution was created that enables the monitoring of sample flow and temperature. This allows for continuous tracking of the system's status through indirect measurements and monitoring via diagnostic algorithms.<\/p>\n<p class=\"MsoNormal\">The result is increased precision in the control of analytical systems and minimized risks associated with malfunctions or a lack of sample flow in the analytical system.<\/p>\n<p class=\"MsoNormal\">\n<\/div>\n<div class=\"kc-elm kc-css-508558 kc-title-wrap\">\n\n\t<h3 class=\"kc_title\">SUMMARY<\/h3>\n<\/div>\n<div class=\"kc-elm kc-css-864765 kc_text_block\"><\/p>\n<p class=\"MsoNormal\">The implementation of modern analytical systems based on remote system diagnostics and the monitoring of sample temperature and flow has significantly improved the efficiency and safety of the industrial plant. The developed solutions, tailored to the user's specific needs, have enhanced the system's precision and reliability, minimizing the risk of downtime and failures.<\/p>\n<p class=\"MsoNormal\">\n<\/div><div class=\"kc-elm kc-css-822081\" style=\"height: 40px; clear: both; width:100%;\"><\/div>\n<div class=\"kc-elm kc-css-862675\">\n\t<a class=\"kc_button\" href=\"http:\/\/www.gassample.com\/mat\/tgtu_GS.pdf\" target=\"_self\" title=\"\" onclick=\"\">\n\t\t<i class=\"fa-file-pdf\"><\/i> DOWNLOAD\t<\/a>\n<\/div>\n<\/div><\/div><div class=\"kc-elm kc-css-193095 kc_col-sm-3 kc_column kc_col-sm-3\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-336877 kc_shortcode kc_single_image\">\n\n        <img decoding=\"async\" src=\"https:\/\/gassample.com\/wp-content\/uploads\/2024\/12\/Czarna-i-Zolta-Wattpad-Okladka-Ksiazki-460-x-1200-px.png\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-361015 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-934927 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-428678 kc-raw-code\"> <a href=\"#top\">BACK TO TOP<\/a><\/div><\/div><\/div><\/div><\/div><\/section><section data-kc-fullwidth=\"content\" class=\"kc-elm kc-css-105248 kc_row\"><div class=\"kc-row-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-676613 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><!--Start Caption Area-->\n<section class=\"caption-area\">\n    <div class=\"container\">\n        <div class=\"row\">\n            <div class=\"col-xl-12\">\n                <div class=\"caption-title float-left\">\n                    <h2>Require assistance with analytics? Contact us - we are here to support you.<\/h2>\n                <\/div>\n                <div class=\"request-button float-right\">\n                    <a class=\"btn-one\" href=\"http:\/\/gassample.com\/en\/contact\">Contact us<\/a>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>\n<!--End Caption Area-->\n<\/div><\/div><\/div><\/div><\/section><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"tpl-king_composer.php","meta":{"slim_seo":{"title":"TGTU - Gas Sample sp. z o.o.","description":"Modernizacja instalacji TGTU III - Jeszcze dok\u0142adniejsze pomiary. MARCIN MASEK- GAS SAMPLE SP. Z O.O. WPROWADZENIE W ramach projektu modernizacji instalacji prz"},"footnotes":""},"class_list":["post-975","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/pages\/975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/comments?post=975"}],"version-history":[{"count":38,"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/pages\/975\/revisions"}],"predecessor-version":[{"id":1357,"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/pages\/975\/revisions\/1357"}],"wp:attachment":[{"href":"https:\/\/gassample.com\/en\/wp-json\/wp\/v2\/media?parent=975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}